BM3RHB series Fuji manual motor starter models available include:
-
BM3RHB-P16 - Fuji manual motor starter, 45 mm frame width, rotary actuator, 0.1 to 0.16 FLA thermal
overload trip rating, 2.1 A instantaneous trip rating.
For UL Type E listing, terminal cover BZ0TCRE and Short Circuit Alarm contact block BZ0TKUAB must be
added to the MMS.
-
BM3RHB-P25 - Fuji manual motor mtarter, 45 mm frame width, rotary actuator, 0.16 to 0.25 FLA thermal
overload trip rating, 3.3 A instantaneous trip rating.
For UL Type E listing, terminal cover BZ0TCRE and Short Circuit Alarm contact block BZ0TKUAB must be
added to the MMS.
-
BM3RHB-P40 - Fuji manual motor starter, 45 mm frame width, rotary actuator, 0.25 to 0.40 FLA thermal
overload trip rating, 5.2 A instantaneous trip rating.
For UL Type E listing, terminal cover BZ0TCRE and Short Circuit Alarm contact block BZ0TKUAB must be
added to the MMS.
-
BM3RHB-P63 - Fuji manual motor starter, 45 mm frame width, rotary actuator, 0.40 to 0.63 A thermal
overload trip rating, 8.2 A instantaneous trip rating.
For UL Type E listing, terminal cover BZ0TCRE and Short Circuit Alarm contact block BZ0TKUAB must be added
to the MMS.
-
BM3RHB-001 - Fuji manual motor starter, 45 mm frame width, rotary actuator, 0.63 to 1.0 FLA thermal
overload trip rating, 13 A instantaneous trip rating.
For UL Type E listing, terminal cover BZ0TCRE and Short Circuit Alarm contact block BZ0TKUAB must be
added to the MMS.
-
BM3RHB-1P6 - Fuji manual motor starter, 45 mm frame width, rotary actuator, 1 to 1.6 FLA thermal
overload trip rating, 20.8 A instantaneous trip rating.
For UL Type E listing, terminal cover BZ0TCRE and Short Circuit Alarm contact block BZ0TKUAB must be
added to the MMS.
-
BM3RHB-2P5 - Fuji manual motor starter, 45 mm frame width, rotary actuator, 1.6 to 2.5 FLA thermal
overload trip rating, 32.5 A instantaneous trip rating.
For UL Type E listing, terminal cover BZ0TCRE and Short Circuit Alarm contact block BZ0TKUAB must be
added to the MMS.
-
BM3RHB-004 - Fuji manual motor starter, 45 mm frame width, rotary actuator, 2.5 to 4 FLA thermal
overload trip rating, 52 A instantaneous trip rating.
For UL Type E listing, terminal cover BZ0TCRE and Short Circuit Alarm contact block BZ0TKUAB must be
added to the MMS.
-
BM3RHB-6P3 - Fuji manual motor starter, 45 mm frame width, rotary actuator, 4 to 6.3 FLA thermal
overload trip rating, 81.9 A instantaneous trip rating.
For UL Type E listing, terminal cover BZ0TCRE and Short Circuit Alarm contact block BZ0TKUAB must be
added to the MMS.
-
BM3RHB-010 - Fuji manual motor starter, 45 mm frame width, rotary actuator, 6.3 to 10 FLA thermal
overload trip rating, 130 A instantaneous trip rating.
For UL Type E listing, terminal cover BZ0TCRE and Short Circuit Alarm contact block BZ0TKUAB must be
added to the MMS.
-
BM3RHB-013 - Fuji manual motor starter, 45 mm frame width, rotary actuator, 9 to 13FLA thermal
overload trip rating, 169 A instantaneous trip rating.
For UL Type E listing, terminal cover BZ0TCRE and Short Circuit Alarm contact block BZ0TKUAB must be
added to the MMS.
-
BM3RHB-016 - Fuji manual motor starter, 45 mm frame width, rotary actuator, 11 to 16A thermal
overload trip rating, 208 A instantaneous trip rating.
For UL Type E listing, terminal cover BZ0TCRE and Short Circuit Alarm contact block BZ0TKUAB must be
added to the MMS.
-
BM3RHB-020 - Fuji manual motor starter, 45 mm frame width, rotary actuator, 14 to 20 FLA thermal
overload trip rating, 260 A instantaneous trip rating.
For UL Type E listing, terminal cover BZ0TCRE and Short Circuit Alarm contact block BZ0TKUAB must be
added to the MMS.
-
BM3RHB-025 - Fuji manual motor starter, 45 mm frame width, rotary actuator, 19 to 25 FLA thermal
overload trip rating, 325 A instantaneous trip rating.
For UL Type E listing, terminal cover BZ0TCRE and Short Circuit Alarm contact block BZ0TKUAB must be
added to the MMS.
-
BM3RHB-032 - Fuji manual motor starter, 45 mm frame width, rotary actuator, 24 to 32 FLA thermal
overload trip rating, 416 A instantaneous trip rating.
For UL Type E listing, terminal cover BZ0TCRE and Short Circuit Alarm contact block BZ0TKUAB must be
added to the MMS.