AutomationDirect
Search
Login | Register
Accounts & Orders
Cart
0
$0.00

Recent Orders

View and Manage | Request Cancellation

Your Account

Account Home

Checkout   $0.00


  • My Orders
  • Product Returns (RMAs)
  • Pay Proforma Invoices
  • Pay Freights
  • Invoices / Invoice Reprint
  • Quotes / Favs / BOMs
  • Packing List Reprint
  • My Product Docs
  • Credit Application
  • Tax Exemption
| Direct Sales in US and Canada | 1-800-633-0405 | About Us | Contact Us | Line Card
Products | Support
| Compare
  
Ordering Tools  
warning Cookies are not enabled on your browser.
Cookies are required for our site. Please enable cookies in your browser preferences to continue.
+
Navigation
+
Shopping Categories
  • Barcode / RFID / Vision
  • Bulk Wire & Cable
  • Cables (Terminated)
  • Circuit Protection / Fuses / Disconnects
  • Communications
  • Drives & Soft Starters
  • Enclosure Thermal Management & Lights
  • Enclosures & Racks
  • Field I/O
  • HMI (Human Machine Interface)
  • Hydraulic Components
  • Motion Control
  • Motor Controls
  • Motors
  • Pneumatic Components
  • Power Products (Electrical)
  • Power Transmission (Mechanical)
  • Process Control & Measurement
  • Programmable Controllers
  • Pushbuttons / Switches / Indicators
  • Relays / Timers
  • Safety
  • Sensors / Encoders
  • Stacklights
  • Structural Frames / Rails
  • Tools & Test Equipment
  • Valves
  • Water (Potable) Components
  • Wiring Solutions
  • Retired Products
+
Learn More
  • Brand Line Card
  • What's New
  • E-newsletter
  • Online PDF Catalog
  • Video Tutorials
  • Company Reviews
  • Learning Library
  • Affordable Training
  • Free Online PLC training
  • Cybersecurity
+
In Depth Product Sites
  • Programmable Logic Controllers
  • Productivity1000 PLCs
  • Productivity2000 PLCs
  • Productivity3000 PLCs
  • ProductivityCODESYS
  • LS Electric XGB Series PLCs
  • ProductivityOpen
  • CLICK PLCs
  • Do-more H2 PLCs or
    Do-more T1H Series
  • Do-more BRX PLCs
  • C-more Touch Panels
  • AC & DC Drives
  • Motion Control Components
  • Servos
  • StrideLinx
  • Pneumatics
+
Product Selectors &
Configuration Utilities
  • PLC Family Selector
  • P1000 PLC Systems
  • P2000 PLC Systems
  • P3000 PLC Systems
  • ProductivityCODESYS
  • CLICK PLC Systems
  • Do-more® BRX PLC Systems
  • LS-Electric® XGB PLC Systems
  • Productivity®Open Systems
  • AC Motors
  • Datalogic® Safety Light Curtains
  • LS-Electric® Servo Systems
  • Nitra® Pneumatic Grippers
  • Object Detection (Sensors)
  • PAL Controller Configurator
  • Precision Gearbox Selector
  • Protos X® Field I/O
  • Quadritalia® Modular Enclosures
  • Stellar® Soft Starters
  • Stepper System Selector
  • SureFrame T-slot Extrusion
  • SureMotion® XYZ Gantry
  • SureServo2® System Selector
  • SureStep® Linear Actuators
  • Timing Belts & Pulleys
  • Werma® Stacklights
  • ZIPLinks

C-more HMI Import RSLogix 500 PLC Tags: PLC5, SLC 500, MicroLogix at AutomationDirect


Related Products

EA9-T6CL-R
EA9-T6CL-R Thumbnail
EA9-T6CL
EA9-T6CL Thumbnail
EA9-T7CL-R
EA9-T7CL-R Thumbnail
EA9-T7CL
EA9-T7CL Thumbnail
EA9-T8CL
EA9-T8CL Thumbnail
EA9-T10CL
EA9-T10CL Thumbnail
EA9-T10WCL
EA9-T10WCL Thumbnail
EA9-T12CL
EA9-T12CL Thumbnail
EA9-T15CL-R
EA9-T15CL-R Thumbnail
EA9-T15CL
EA9-T15CL Thumbnail
EA9-PGMSW
EA9-PGMSW Thumbnail


To learn more: https://www.AutomationDirect.com/C-more?utm_source=zZiWMdZyKUY&utm_medium=VideoTeamDescription

(VID-CR-0014)

In this video, it is detailed how to quickly import your RSLogix 500 PLC project tags, from your RSLogix 500 Programming software, into your C-more HMI Touch panel. This includes the PLC5, SLC 500 CPUs, MicroLogix 1000, MicroLogix 1100, MicroLogix 1200, Micrologix 1400, and the MicroLogix 1500 PLCs. This video is part of the C-more setup videos that give direction on how to import tags from different platforms into the C-more Industrial HMI software.
*** Software version used: 6.42

Online Support Page: https://community.automationdirect.com/s/?utm_source=zZiWMdZyKUY&utm_medium=VideoTeamDescription

**Please check our website for our most up-to-date product pricing and availability.


Hide Transcript
View Transcript

With the C-more HMI you can quickly integrate your RSLogix 500 project tags. This process works for all these CPUs, that are programmed using the RSLogix 500. So, open up you RSLogix 500 project. Now, the big caveat with this tag import is that you can only import memory addresses that have the symbols assigned to that address. For example, if I open up my data files, here you can see the “symbols” that I have applied to these addresses. If you do not have these symbol nicknames applied to these registers, they will not import into the C-more. To start the import process, go to Tools, Database and then ASCII Export. Select here, on the CSV tab and this is the export that you are looking for. Select OK and save the file. Open up the C-more software and you will see this start up wizard. Name your project, select your panel type, and under PLC Protocol you have quite a few options for this connection. These are the serial connections for these CPUS, and these are for ethernet for the different processors. Now, I am going to continue this demonstration with the ethernet connection to a MicroLogix 1400 CPU. Now, click here on Protocol setup and you will need to define the IP address of the MicroLogix CPU. For the most part these defaults will work for most systems. Once you are done, click OK and then OK once again. That starts your project, now let’s import the tags. There are two ways you can import your tags. You can go to File, Import and then Tag Name Database or open up the Tag Tame Database from here and select Import. Select the CSV file we created earlier. Select the device that you are connecting these tags with. If you are wanting to append the tag names that you are importing, place that text here. And if you would like to overwrite existing tags, select this option. Once you have those options setup, select to Import. My tags successfully imported, and I can see them now in my tag database. I can also select here and use the filter to display only the tags for that device. Now that everything is imported, make sure to setup the IP address of the C-more. Select here, on Ethernet Port. Enter in the IP Address info. Once that is done send the project to the panel and start building you control screens. And that is just how easy it is to integrate your C-more with your RSLogix500 CPU. If you have any question on the C-more line, please comment below or call into our Free Technical Support department. To see more videos on the C-more line select here. And make sure to select here to subscribe to our YouTube channel for upcoming products and solutions.



No data returned!
An error has occurred! Please contact support
Videos Home > C-more HMI Import RSLogix 500 PLC Tags: PLC5, SLC 500, MicroLogix at AutomationDirect
Contact, Connect & More
Sign Up
to receive:
FREE e-Newsletter
sign up today!
Connect With Us
Social Media Channels:
linkedin    facebook    x    instagram    youtube
Company Information
About Us
Brand Line Card
System Integrator Program
International Sales
Panel Builder Program
Site Help
Company Reviews
Download Price List
Contact Us
Contact Options
1-800-633-0405
Monday - Friday
9 a.m. - 6 p.m. ET
excluding holidays
Career Opportunities
Voted #1 mid-sized employer in Atlanta
We're a great place to work!
Check out our job openings

Need Training?
Affordable Training by Interconnecting Automation
Free Online PLC Training
FREE Video Tutorials
Information & News
What's New / In The News
FREE e-Newsletter
Automation Notebook
Product Literature
White Papers
News, Product and Training Bulletins
E-Books
Shop with confidence
Checked   Safe & Secure
payment methods


We accept VISA, MasterCard, Discover, American Express, PayPal or company purchase orders.
AutomationDirect

BBB Accredited

Voted #1 mid-sized employer in Atlanta
Check out our job openings

Copyright © 1999-2025 AutomationDirect.  ALL RIGHTS RESERVED.
Site Map     Send Us your Feedback     Unsubscribe     Email Preferences     Legal & Business Policies     YouTube Terms of Service
Clear login credentials



Back to Top


spinner Updating...
Info
„