AutomationDirect
Search
Login | Register
Accounts & Orders
Cart
0
$0.00

Recent Orders

View and Manage | Request Cancellation

Your Account

Account Home

Checkout   $0.00


  • My Orders
  • Product Returns (RMAs)
  • Pay Proforma Invoices
  • Pay Freights
  • Invoices / Invoice Reprint
  • Quotes / Favs / BOMs
  • Packing List Reprint
  • My Product Docs
  • Credit Application
  • Tax Exemption
| Direct Sales in US and Canada | 1-800-633-0405 | About Us | Contact Us | Line Card
Products | Support
| Compare
  
Ordering Tools  
warning Cookies are not enabled on your browser.
Cookies are required for our site. Please enable cookies in your browser preferences to continue.
Our offices will be closed Monday, May 26th, for Memorial Day. Normal ADC shipping policies are in effect.
+
Navigation
+
Shopping Categories
  • Barcode / RFID / Vision
  • Bulk Wire & Cable
  • Cables (Terminated)
  • Circuit Protection / Fuses / Disconnects
  • Communications
  • Drives & Soft Starters
  • Enclosure Thermal Management & Lights
  • Enclosures & Racks
  • Field I/O
  • HMI (Human Machine Interface)
  • Hydraulic Components
  • Motion Control
  • Motor Controls
  • Motors
  • Pneumatic Components
  • Power Products (Electrical)
  • Power Transmission (Mechanical)
  • Process Control & Measurement
  • Programmable Controllers
  • Pushbuttons / Switches / Indicators
  • Relays / Timers
  • Safety
  • Sensors / Encoders
  • Stacklights
  • Structural Frames / Rails
  • Tools & Test Equipment
  • Valves
  • Water (Potable) Components
  • Wiring Solutions
  • Retired Products
+
Learn More
  • Brand Line Card
  • What's New
  • E-newsletter
  • Online PDF Catalog
  • Video Tutorials
  • Company Reviews
  • Learning Library
  • Affordable Training
  • Free Online PLC training
  • Cybersecurity
+
In Depth Product Sites
  • Programmable Logic Controllers
  • Productivity1000 PLCs
  • Productivity2000 PLCs
  • Productivity3000 PLCs
  • ProductivityCODESYS
  • LS Electric XGB Series PLCs
  • ProductivityOpen
  • CLICK PLCs
  • Do-more H2 PLCs or
    Do-more T1H Series
  • Do-more BRX PLCs
  • C-more Touch Panels
  • AC & DC Drives
  • Motion Control Components
  • Servos
  • StrideLinx
  • Pneumatics
+
Product Selectors &
Configuration Utilities
  • PLC Family Selector
  • P1000 PLC Systems
  • P2000 PLC Systems
  • P3000 PLC Systems
  • ProductivityCODESYS
  • CLICK PLC Systems
  • Do-more® BRX PLC Systems
  • LS-Electric® XGB PLC Systems
  • Productivity®Open Systems
  • AC Motors
  • Datalogic® Safety Light Curtains
  • LS-Electric® Servo Systems
  • Nitra® Pneumatic Grippers
  • Object Detection (Sensors)
  • PAL Controller Configurator
  • Precision Gearbox Selector
  • Protos X® Field I/O
  • Quadritalia® Modular Enclosures
  • Stellar® Soft Starters
  • Stepper System Selector
  • SureFrame T-slot Extrusion
  • SureMotion® XYZ Gantry
  • SureServo2® System Selector
  • SureStep® Linear Actuators
  • Timing Belts & Pulleys
  • Werma® Stacklights
  • ZIPLinks

C-more Micro HMI Debug Comm Issues with PLC from AutomationDirect


Related Products

EA1-S3MLW
EA1-S3MLW Thumbnail
EA3-T6CL
EA3-T6CL Thumbnail
EA3-T4CL
EA3-T4CL Thumbnail
EA3-S3ML
EA3-S3ML Thumbnail
EA3-S3ML-R
EA3-S3ML-R Thumbnail
EA3-S3ML-RN
EA3-S3ML-RN Thumbnail
EA1-TCL-M
EA1-TCL-M Thumbnail
EA-MG-PGM-CBL
EA-MG-PGM-CBL Thumbnail


To learn more: https://www.automationdirect.com/C-more-micro?utm_source=Qz1UKU6gv0s&utm_medium=VideoTeamDescription

(VID-CK-0083)

This videos shows how to troubleshoot communications problems between the C-more micro graphic panel and PLC.

Online Support Page: https://community.automationdirect.com/s/?utm_source=Qz1UKU6gv0s&utm_medium=VideoTeamDescription

**Please check our website for our most up-to-date product pricing and availability.


Hide Transcript
View Transcript

If you can’t communicate with the PLC, check each of the following: 1. Make sure you are using the correct com port. All of the ports on the C-More Micro are labeled so look real close and see. Usually the 6 pin connector is always port 1. Or on the larger panels the USB port is port 1. But again, check the labels on the panel. 2. Make sure the correct com port is selected in the project. Under Panel Manager, which you can find under the Navigations Windows Function Tab - Panel Manager … you can see all the devices and which com ports they are connected to on the panel Note that this is the CMORE MICRO com port – NOT the device’s com port or the PC’s com port. Click on the device and you can see all of the com port parameters associated with that com port. Again, these are the com port parameters for THIS com port on the C-More Micro. They are not the com port parameters of the PLC or the Device you are connected to. 3. Verify that the C-More Micro com port settings match the comport setting of the PLC project. Let’s bring up the com port settings for our panel. That’s under the navigations windows Function Tab – panel manager. We click on the device connected to com port 1, which is the one we are interested in right now … and we see all the com port parameters. Keep in mind these are the com port parameters of the panel’s serial port – not the PLC. So let’s put the panel up here and bring up the com port settings from the PLC project. This is from the Click PLC software. Here’s our panel, here’s our PLC. Comparing side-by-side … we see that they are both operating on the same address … same baud rate, same parity, same stop but, and 8 communication bits which are assumed over here on the panel. So my Panel Serial Port Setting Match my PLC serial port settings. So we should be good to go. 4. Verify that the comport on the C-More Micro is good. Bring up the setup screen on the C-More Micro – I have a simulated version here – go to the test menu – and there is a serial port loopback test. You will need a loop back cable/adapter which you can make yourself using the instructions in the hardware manual. If you go to the C-More Micro Page, I’m using this panel so I’ll click on his manual, I’m going to go down to chapter 5 in this manual which is the setup screen … and in that section of the manual there is actually a sub-paragraph on test menu for serial port loopback test – test menu – serial port loop back test. So here is a picture of the cable that gets plugged in … and what you have to do – that is just short pins 3 and 4 to make a loopback tester. If you want to test serial port 2, you need to loop back on these pins here. Once you have built that connector and attached it to the serial port, you can run a test – it says bytes sent, receive Counts, Error Counts. This is testing serial port 1. To test serial port 2 – you click on serial port 2. 5. Finally, the last hint on how to debug com issues, number 5, is to make sure the PLC is grounded and its using the same ground as the C-More Micro Panel. That’s all there is to debugging com issues on your C-More Micro – be sure to check out the other videos in this series. And as always, please send us any topics you would like to see covered – or - any other comments for that matter – we appreciate the feedback



No data returned!
An error has occurred! Please contact support
Videos Home > C-more Micro HMI Debug Comm Issues with PLC from AutomationDirect
Contact, Connect & More
Sign Up
to receive:
FREE e-Newsletter
sign up today!
Connect With Us
Social Media Channels:
linkedin    facebook    x    instagram    youtube
Company Information
About Us
Brand Line Card
System Integrator Program
International Sales
Panel Builder Program
Site Help
Company Reviews
Download Price List
Contact Us
Contact Options
1-800-633-0405
Monday - Friday
9 a.m. - 6 p.m. ET
excluding holidays
Career Opportunities
Voted #1 mid-sized employer in Atlanta
We're a great place to work!
Check out our job openings

Need Training?
Affordable Training by Interconnecting Automation
Free Online PLC Training
FREE Video Tutorials
Information & News
What's New / In The News
FREE e-Newsletter
Automation Notebook
Product Literature
White Papers
News, Product and Training Bulletins
E-Books
Shop with confidence
Checked   Safe & Secure
payment methods


We accept VISA, MasterCard, Discover, American Express, PayPal or company purchase orders.
AutomationDirect

BBB Accredited

Voted #1 mid-sized employer in Atlanta
Check out our job openings

Copyright © 1999-2025 AutomationDirect.  ALL RIGHTS RESERVED.
Site Map     Send Us your Feedback     Unsubscribe     Email Preferences     Legal & Business Policies     YouTube Terms of Service
Clear login credentials



Back to Top


spinner Updating...
Info