AutomationDirect
Search
Login | Register
Accounts & Orders
Cart
0
$0.00

Recent Orders

View and Manage | Request Cancellation

Your Account

Account Home

Checkout   $0.00


  • My Orders
  • Product Returns (RMAs)
  • Pay Proforma Invoices
  • Pay Freights
  • Invoices / Invoice Reprint
  • Quotes / Favs / BOMs
  • Packing List Reprint
  • My Product Docs
  • Credit Application
  • Tax Exemption
| Direct Sales in US and Canada | 1-800-633-0405 | About Us | Contact Us | Line Card
Products | Support
| Compare
  
Ordering Tools  
warning Cookies are not enabled on your browser.
Cookies are required for our site. Please enable cookies in your browser preferences to continue.
+
Navigation
+
Shopping Categories
  • Barcode / RFID / Vision
  • Bulk Wire & Cable
  • Cables (Terminated)
  • Circuit Protection / Fuses / Disconnects
  • Communications
  • Drives & Soft Starters
  • Enclosure Thermal Management & Lights
  • Enclosures & Racks
  • Field I/O
  • HMI (Human Machine Interface)
  • Hydraulic Components
  • Motion Control
  • Motor Controls
  • Motors
  • Pneumatic Components
  • Power Products (Electrical)
  • Power Transmission (Mechanical)
  • Process Control & Measurement
  • Programmable Controllers
  • Pushbuttons / Switches / Indicators
  • Relays / Timers
  • Safety
  • Sensors / Encoders
  • Stacklights
  • Structural Frames / Rails
  • Tools & Test Equipment
  • Valves
  • Water (Potable) Components
  • Wiring Solutions
  • Retired Products
+
Learn More
  • Brand Line Card
  • What's New
  • E-newsletter
  • Online PDF Catalog
  • Video Tutorials
  • Company Reviews
  • Learning Library
  • Affordable Training
  • Free Online PLC training
  • Cybersecurity
+
In Depth Product Sites
  • Programmable Logic Controllers
  • Productivity1000 PLCs
  • Productivity2000 PLCs
  • Productivity3000 PLCs
  • ProductivityCODESYS
  • LS Electric XGB Series PLCs
  • ProductivityOpen
  • CLICK PLCs
  • Do-more H2 PLCs or
    Do-more T1H Series
  • Do-more BRX PLCs
  • C-more Touch Panels
  • AC & DC Drives
  • Motion Control Components
  • Servos
  • StrideLinx
  • Pneumatics
+
Product Selectors &
Configuration Utilities
  • PLC Family Selector
  • P1000 PLC Systems
  • P2000 PLC Systems
  • P3000 PLC Systems
  • ProductivityCODESYS
  • CLICK PLC Systems
  • Do-more® BRX PLC Systems
  • LS-Electric® XGB PLC Systems
  • Productivity®Open Systems
  • Datalogic® Safety Light Curtains
  • LS-Electric® Servo Systems
  • Nitra® Pneumatic Grippers
  • Object Detection (Sensors)
  • PAL Controller Configurator
  • Precision Gearbox Selector
  • Protos X® Field I/O
  • Quadritalia® Modular Enclosures
  • Stellar® Soft Starters
  • Stepper System Selector
  • SureFrame T-slot Extrusion
  • SureMotion® XYZ Gantry
  • SureServo2® System Selector
  • SureStep® Linear Actuators
  • Timing Belts & Pulleys
  • Werma® Stacklights
  • ZIPLinks

C-more Micro HMI Send Project To Panel from AutomationDirect


Related Products

EA1-S3MLW
EA1-S3MLW Thumbnail
EA3-T6CL
EA3-T6CL Thumbnail
EA3-T4CL
EA3-T4CL Thumbnail
EA3-S3ML
EA3-S3ML Thumbnail
EA3-S3ML-R
EA3-S3ML-R Thumbnail
EA3-S3ML-RN
EA3-S3ML-RN Thumbnail
EA1-TCL-M
EA1-TCL-M Thumbnail
EA-MG-PGM-CBL
EA-MG-PGM-CBL Thumbnail


To learn more: https://www.automationdirect.com/C-more-micro?utm_source=qGBKj-UPKBk&utm_medium=VideoTeamDescription

(VID-CK-0067)

This videos shows how to send a project to the C-more Micro panel from the programming software.

Online Support Page: https://community.automationdirect.com/s/?utm_source=qGBKj-UPKBk&utm_medium=VideoTeamDescription

**Please check our website for our most up-to-date product pricing and availability.


Hide Transcript
View Transcript

Once you have completed your project, downloading it to the panel is easy, just click on “Send” Verify that the correct Com Port is selected – if you’re are not sure .. Click on this DETAILS button .. it will list all the comports being used in your system and what they are being used for - let’s see, our cable is plugged into com 4 and we selected com4 4 so we are in good shape. Note that by checking this box, you can save your entire project to the panel – so in addition to the executable that runs the panel, you can also store all of your project source files and retrieve it later – this is an excellent way to keep our source project handy and backed up - that way you know absolutely that this is the project file that was used to create this panel! Just make sure you have enough room on the panel to store it - We have plenty of room here so we are definitely going to save the project on the panel for future reference. This does add a little time to the transfer, but it is well worth it knowing you have the original source project backed up with the panel. Here are the memory usage stats, as you can see we are not using much here. Finally BEFORE transferring, make sure the panel is showing the setup screen. I’m going to hold down the F1 and F5 key at the same time … setup screen pops up – it looks like this … and now we are ready to do a transfer. If you don’t get this screen, or this screen doesn’t come up, see the video on How to enable the setup screen, or the video on How to prevent access to setup screen. Either one will show you how to work around that. Once the panel is in Set up Screen Mode, just hit TRANSFER. You can see the status of the transfers and then we are done. First it is loading the runtime file into the panel, and because we asked it to, now it is transferring the project source files into the panel too – it only takes a few additional seconds. The project is now up and running on the panel I have here on my desk. If there is an error, you will get this message. Let’s go ahead and force it here – I’m going to remove the cable from this panel so I can’t download to it .. Let’s go ahead and do SEND … and hit Transfer. And here is that error message. Whenever the software can’t talk to the panel, you will always get this error message. The issue is almost always one of these three things: - 1. Panel is not on the Setup Screen (you didn’t push the F1 and F5 function keys for 3 seconds to get the setup screen ..) - 2. Cable is not connected – which is exactly the problem in this case… - 3. You are not using the correct com port assigned to that USB adapter. Make sure all of those are setup and you should be good to go. That’s all there is to sending your project down to your panel – be sure to check out the other videos in this series. And as always, please send us any topics you would like to see covered – or - any other comments for that matter – we appreciate the feedback



No data returned!
An error has occurred! Please contact support
Videos Home > C-more Micro HMI Send Project To Panel from AutomationDirect
Contact, Connect & More
Sign Up
to receive:
FREE e-Newsletter
sign up today!
Connect With Us
Social Media Channels:
linkedin    facebook    x    instagram    youtube
Company Information
About Us
Brand Line Card
System Integrator Program
International Sales
Panel Builder Program
Site Help
Company Reviews
Download Price List
Contact Us
Contact Options
1-800-633-0405
Monday - Friday
9 a.m. - 6 p.m. ET
excluding holidays
Career Opportunities
Voted #1 mid-sized employer in Atlanta
We're a great place to work!
Check out our job openings

Need Training?
Affordable Training by Interconnecting Automation
Free Online PLC Training
FREE Video Tutorials
Information & News
What's New / In The News
FREE e-Newsletter
Automation Notebook
Product Literature
White Papers
News, Product and Training Bulletins
E-Books
Shop with confidence
Checked   Safe & Secure
payment methods


We accept VISA, MasterCard, Discover, American Express, PayPal or company purchase orders.
AutomationDirect

BBB Accredited

Voted #1 mid-sized employer in Atlanta
Check out our job openings

Copyright © 1999-2025 AutomationDirect.  ALL RIGHTS RESERVED.
Site Map     Send Us your Feedback     Unsubscribe     Email Preferences     Legal & Business Policies     YouTube Terms of Service
Clear login credentials



Back to Top


spinner Updating...
Info