AutomationDirect
Search
Login | Register
Accounts & Orders
Cart
0
$0.00

Recent Orders

View and Manage | Request Cancellation

Your Account

Account Home

Checkout   $0.00


  • My Orders
  • Product Returns (RMAs)
  • Pay Proforma Invoices
  • Pay Freights
  • Invoices / Invoice Reprint
  • Quotes / Favs / BOMs
  • Packing List Reprint
  • My Product Docs
  • Credit Application
  • Tax Exemption
| Direct Sales in US and Canada | 1-800-633-0405 | About Us | Contact Us | Line Card
Products | Support
| Compare
  
Ordering Tools  
warning Cookies are not enabled on your browser.
Cookies are required for our site. Please enable cookies in your browser preferences to continue.
We will be performing maintenance on several web store related systems this evening, Wednesday, May 14th beginning around 8:00 PM ET. We expect this maintenance to be completed prior to 12:00am ET (Midnight).
There may be brief outages and some store features may be unavailable periodically during this time. We regret any inconvenience this may cause.
+
Navigation
+
Shopping Categories
  • Barcode / RFID / Vision
  • Bulk Wire & Cable
  • Cables (Terminated)
  • Circuit Protection / Fuses / Disconnects
  • Communications
  • Drives & Soft Starters
  • Enclosure Thermal Management & Lights
  • Enclosures & Racks
  • Field I/O
  • HMI (Human Machine Interface)
  • Hydraulic Components
  • Motion Control
  • Motor Controls
  • Motors
  • Pneumatic Components
  • Power Products (Electrical)
  • Power Transmission (Mechanical)
  • Process Control & Measurement
  • Programmable Controllers
  • Pushbuttons / Switches / Indicators
  • Relays / Timers
  • Safety
  • Sensors / Encoders
  • Stacklights
  • Structural Frames / Rails
  • Tools & Test Equipment
  • Valves
  • Water (Potable) Components
  • Wiring Solutions
  • Retired Products
+
Learn More
  • Brand Line Card
  • What's New
  • E-newsletter
  • Online PDF Catalog
  • Video Tutorials
  • Company Reviews
  • Learning Library
  • Affordable Training
  • Free Online PLC training
  • Cybersecurity
+
In Depth Product Sites
  • Programmable Logic Controllers
  • Productivity1000 PLCs
  • Productivity2000 PLCs
  • Productivity3000 PLCs
  • ProductivityCODESYS
  • LS Electric XGB Series PLCs
  • ProductivityOpen
  • CLICK PLCs
  • Do-more H2 PLCs or
    Do-more T1H Series
  • Do-more BRX PLCs
  • C-more Touch Panels
  • AC & DC Drives
  • Motion Control Components
  • Servos
  • StrideLinx
  • Pneumatics
+
Product Selectors &
Configuration Utilities
  • PLC Family Selector
  • P1000 PLC Systems
  • P2000 PLC Systems
  • P3000 PLC Systems
  • ProductivityCODESYS
  • CLICK PLC Systems
  • Do-more® BRX PLC Systems
  • LS-Electric® XGB PLC Systems
  • Productivity®Open Systems
  • AC Motors
  • Datalogic® Safety Light Curtains
  • LS-Electric® Servo Systems
  • Nitra® Pneumatic Grippers
  • Object Detection (Sensors)
  • PAL Controller Configurator
  • Precision Gearbox Selector
  • Protos X® Field I/O
  • Quadritalia® Modular Enclosures
  • Stellar® Soft Starters
  • Stepper System Selector
  • SureFrame T-slot Extrusion
  • SureMotion® XYZ Gantry
  • SureServo2® System Selector
  • SureStep® Linear Actuators
  • Timing Belts & Pulleys
  • Werma® Stacklights
  • ZIPLinks

XEM Modbus/TCP Client Configuration - LS Electric XGB PLC from AutomationDirect



To learn more: https://www.automationdirect.com/ls-electric-plc?utm_source=BAPkl9v-8EY&utm_medium=VideoTeamDescription

(VID-XG-0092)

LS XGB Help File Video: LP201-2

XG5000 V4.77 2024-06-28

To view the LS XGB Help File please visit: https://cdn.automationdirect.com/static/helpfiles/ls_plc/Content/Home.htm

**Please check our website for our most up-to-date product pricing and availability.

Related AutomationDirect.com Part Numbers: N/A


Hide Transcript
View Transcript

The XGB PLC offers many ways to communicate over EtherNet. The on-board EtherNet port is referred to as the “Internal FENet,” and allows Modbus/TCP and XGT protocols. For Modbus/TCP, the PLC allows configuration as both a Modbus Slave and Master. In LS documentation Modbus Slave is also called Modbus Server, and Modbus Master is also called Modbus Client. The Modbus Server and Client functions for the XGB PLC can share up to 16 concurrent connections. Let’s set up the XGB PLC as a Modbus client. The first step is to set the TCP/IP settings. To do this we will go to the “Project Window” on the left side of the screen and double-click on “Internal FEnet.” This will open the “Standard Settings – FEnet” pop-up window. Here we can set our IP address, Subnet Mask, Gateway, and DNS Server if needed. We can also use DHCP to allow a local DHCP server to automatically configure the IP settings for the PLC. Using DHCP can lead to potential network routing or unintentional IP address issues so be careful when enabling this setting. Once we configure these settings, we are ready for the Modbus/TCP configuration. If we are using the PLC as a Modbus client, we need to verify the “Number of Dedicated Connections” field has been set to something less than 16 to allow our client to occupy one of the Modbus connections. Ours is set to the default of 3, and we won’t be setting up more than 13 client connections so that number is fine. Now we need to set up a peer-to-peer connection for the “Internal FEnet” network. To do this we will go to the “Project” window on the left side of the screen. Under the “Network Configuration” heading we can right-click on our “Internal FEnet” network and go to “Add Item>P2P Communication.” This opens the “Select P2P” pop-up window, and there will be a drop down with a peer-to-peer connection available for selection. Since we only have one available port it only shows connection 2 as available. Once we select our connection and click “OK,” we see a new peer-to-peer connection added under the “Internal FEnet” network subheading. We can now set up our Modbus client connections. We double-click on P2P Channel and the “Channel Setting” pop-up window opens. We see there are 13 connections available numbered 0-12. If we had put a number other than 3 into the “Number of Dedicated Connections” we would see the number available here adjusted accordingly. Let’s set connection 0 up as a Modbus Client. Under the “P2P Driver” column we can select “Modbus TCP client” from the drop-down list. Don’t worry about the Operation Mode column. This will list server settings. As we are using this channel as a client, it will ignore that column. Once we have set channel 0 as “Modbus TCP Client,” it will auto-populate the TCP/UDP, Client/Server, and Port Number fields. We can then set the IP address of the Modbus server we wish to communicate with. In our example we are going to control a GS20 variable frequency drive located at 192.168.27.105. We can then select “OK” to confirm our settings. Now we need to create a “Peer-to-Peer” entry. We go under the “P2P 02(Internal)” sub-heading and double click on P2P Block. This will open the “LSPLC – P2P 02” tab in the main programming window. We can select channel 0 from the drop-down menu and it will automatically set the driver to the “Modbus TCP client” we configured in the “P2P Channel” window. We leave “Header” blank, and then select whether this will be a Modbus Read or a Modbus Write. Let’s start with a Read function to read the current drive speed. For the “Conditional Flag” column, we can select any Boolean direct or flag variable. We will use the system flag _T200MS.” This will cause the PLC to send every 200ms. If we wanted to use a program determined message send rate, we could use a %MX memory location and then control that address with our logic. For the “Command Type” column we can select single, to read or write a single bit or register, or continuous to read or write a range of consecutive bits or registers. We will select single for our read. The data type can be bit or word. If we wanted to do a coil or input function code, we would select “bit.” For any of the register function codes we would select “Word.” In our example we wish to read the drives speed, which is a word register. “Data Size” corresponds to the number of bits or words we want to read or write. Since we are using a “Single” Command type, this is hard coded to 1. If we were using the “Continuous” command type we would put the number of data blocks we wanted to read or write. “Destination Station” is LS nomenclature for node address. This is the unique identifier for a specific serial node on a Modbus network. For Modbus/TCP servers with a unique IP address, this can be any number. The GS20’s communication card, however, is a Modbus Gateway, that has a node address for its drive data at node 1 and a node address for the drive’s internal PLC at node 2. We will have to set the “Destination Station” to 1 since we want to read from and write to the drive data. The last field is the Variable Setting Content. We configure this by clicking the “Setting” button. This opens the “Variable Setting” pop-up window. Because we aren’t doing communications from one LS PLC to another over the XGT protocol, we don’t use the “Counterpart CPU” area. The “Read area” is the memory location in hex that we will read the data from in the server, and the “Save area” is the direct variable address to which the XGB PLC will store the information. The “Address” area is automatically assigned by the PLC, so we will leave it alone. For our example, we want to read the commanded speed from the drive. If we look in the drive manual, we see that this resides at hex address 0x2102. In XG5000 we use a 3 or a 4 precursor to select the Modbus function code. In our case we want to read a holding register, not an input register, so we will use 0x42102. We would use a 0 or 1 precursor for a bit. We will write this to the internal memory address %MW100. That address was arbitrarily selected and can be any available direct variable address. Because the %M range of memory addresses is reserved for functions just like this, we strongly recommend using that range to avoid unintentionally overwriting PLC or communication data. We have now set up our Modbus read message. We will do the same for the “write” message to control the drive preset speed. We use Index 1, set it to channel 0, make it a P2P “Write” function with an update rate of 200ms, a command type of “Single,” Data Type of Word. For our “Variable Content Settings” we look in the drive manual and see that the address for controlling the drive frequency is 0x2001 so we will use 0x42001 and we will write the data from %MW101. We will write this project to our PLC, reset the PLC to ensure all the network changes were made effective, and then go online with our PLC in monitor mode. If we add our read and write variable words to our “Monitor 2” tab, we see that they are both currently 0. If we change %MW101, which is our speed command write, to 1000, we see that the value changes in the drive and is read back to %MW100. We are now able to control our drive speed from our XGB PLC using Modbus/TCP!



No data returned!
An error has occurred! Please contact support
Videos Home > XEM Modbus/TCP Client Configuration - LS Electric XGB PLC from AutomationDirect
Contact, Connect & More
Sign Up
to receive:
FREE e-Newsletter
sign up today!
Connect With Us
Social Media Channels:
linkedin    facebook    x    instagram    youtube
Company Information
About Us
Brand Line Card
System Integrator Program
International Sales
Panel Builder Program
Site Help
Company Reviews
Download Price List
Contact Us
Contact Options
1-800-633-0405
Monday - Friday
9 a.m. - 6 p.m. ET
excluding holidays
Career Opportunities
Voted #1 mid-sized employer in Atlanta
We're a great place to work!
Check out our job openings

Need Training?
Affordable Training by Interconnecting Automation
Free Online PLC Training
FREE Video Tutorials
Information & News
What's New / In The News
FREE e-Newsletter
Automation Notebook
Product Literature
White Papers
News, Product and Training Bulletins
E-Books
Shop with confidence
Checked   Safe & Secure
payment methods


We accept VISA, MasterCard, Discover, American Express, PayPal or company purchase orders.
AutomationDirect

BBB Accredited

Voted #1 mid-sized employer in Atlanta
Check out our job openings

Copyright © 1999-2025 AutomationDirect.  ALL RIGHTS RESERVED.
Site Map     Send Us your Feedback     Unsubscribe     Email Preferences     Legal & Business Policies     YouTube Terms of Service
Clear login credentials



Back to Top


spinner Updating...
Info
„