AutomationDirect
Search
Login | Register
Accounts & Orders
Cart
0
$0.00

Recent Orders

View and Manage | Request Cancellation

Your Account

Account Home

Checkout   $0.00


  • My Orders
  • Product Returns (RMAs)
  • Pay Proforma Invoices
  • Pay Freights
  • Invoices / Invoice Reprint
  • Quotes / Favs / BOMs
  • Packing List Reprint
  • My Product Docs
  • Credit Application
  • Tax Exemption
| Direct Sales in US and Canada | 1-800-633-0405 | About Us | Contact Us | Line Card
Products | Support
| Compare
  
Ordering Tools  
warning Cookies are not enabled on your browser.
Cookies are required for our site. Please enable cookies in your browser preferences to continue.
Our offices will be closed Monday, May 26th, for Memorial Day. Normal ADC shipping policies are in effect.
+
Navigation
+
Shopping Categories
  • Barcode / RFID / Vision
  • Bulk Wire & Cable
  • Cables (Terminated)
  • Circuit Protection / Fuses / Disconnects
  • Communications
  • Drives & Soft Starters
  • Enclosure Thermal Management & Lights
  • Enclosures & Racks
  • Field I/O
  • HMI (Human Machine Interface)
  • Hydraulic Components
  • Motion Control
  • Motor Controls
  • Motors
  • Pneumatic Components
  • Power Products (Electrical)
  • Power Transmission (Mechanical)
  • Process Control & Measurement
  • Programmable Controllers
  • Pushbuttons / Switches / Indicators
  • Relays / Timers
  • Safety
  • Sensors / Encoders
  • Stacklights
  • Structural Frames / Rails
  • Tools & Test Equipment
  • Valves
  • Water (Potable) Components
  • Wiring Solutions
  • Retired Products
+
Learn More
  • Brand Line Card
  • What's New
  • E-newsletter
  • Online PDF Catalog
  • Video Tutorials
  • Company Reviews
  • Learning Library
  • Affordable Training
  • Free Online PLC training
  • Cybersecurity
+
In Depth Product Sites
  • Programmable Logic Controllers
  • Productivity1000 PLCs
  • Productivity2000 PLCs
  • Productivity3000 PLCs
  • ProductivityCODESYS
  • LS Electric XGB Series PLCs
  • ProductivityOpen
  • CLICK PLCs
  • Do-more H2 PLCs or
    Do-more T1H Series
  • Do-more BRX PLCs
  • C-more Touch Panels
  • AC & DC Drives
  • Motion Control Components
  • Servos
  • StrideLinx
  • Pneumatics
+
Product Selectors &
Configuration Utilities
  • PLC Family Selector
  • P1000 PLC Systems
  • P2000 PLC Systems
  • P3000 PLC Systems
  • ProductivityCODESYS
  • CLICK PLC Systems
  • Do-more® BRX PLC Systems
  • LS-Electric® XGB PLC Systems
  • Productivity®Open Systems
  • AC Motors
  • Datalogic® Safety Light Curtains
  • LS-Electric® Servo Systems
  • Nitra® Pneumatic Grippers
  • Object Detection (Sensors)
  • PAL Controller Configurator
  • Precision Gearbox Selector
  • Protos X® Field I/O
  • Quadritalia® Modular Enclosures
  • Stellar® Soft Starters
  • Stepper System Selector
  • SureFrame T-slot Extrusion
  • SureMotion® XYZ Gantry
  • SureServo2® System Selector
  • SureStep® Linear Actuators
  • Timing Belts & Pulleys
  • Werma® Stacklights
  • ZIPLinks

Datalogic TL Series Contrast Sensor Setup - How To 1 of 4 from AutomationDirect


Related Products

S8-PR-3-W13-NN
S8-PR-3-W13-NN Thumbnail
S8-PR-3-W13-PP
S8-PR-3-W13-PP Thumbnail
S8-PR-5-W13-NN
S8-PR-5-W13-NN Thumbnail
S8-PR-5-W13-PP
S8-PR-5-W13-PP Thumbnail
S8-MR-5-W13-NN
S8-MR-5-W13-NN Thumbnail
S8-MR-5-W13-PP
S8-MR-5-W13-PP Thumbnail
TL46-W-815
TL46-W-815 Thumbnail
TL46-W-815L
TL46-W-815L Thumbnail
TL46-WL-815
TL46-WL-815 Thumbnail
TL46-WL-815L
TL46-WL-815L Thumbnail
TL46-WJ-815
TL46-WJ-815 Thumbnail
TL46-WJ-815L
TL46-WJ-815L Thumbnail
ST-S8-FRM
ST-S8-FRM Thumbnail
ST-5072
ST-5072 Thumbnail


To learn more: https://www.automationdirect.com/contrast-sensor?utm_source=eIXxMm98LLY&utm_medium=VideoTeamDescription

(VID-PH-0015)

This video covers setting up the Datalogic print mark contrast sensors TL series. These are designed to detect the difference in the wavelength of the reflected light between a target mark and background, the contrast sensors use RGB light emission with automatic selection, and feature teach-in sensitivity adjustment, and selectable light on/dark on outputs.

Online Support Page: https://community.automationdirect.com/s/?utm_source=eIXxMm98LLY&utm_medium=VideoTeamDescription

**Please check our website for our most up-to-date product pricing and availability.


Hide Transcript
View Transcript

In this HOW TO video, we will cover the basics of wiring and setting up one of AutomationDirects contrast sensors from the brand Datalogic. I am currently using model number: Tl46-WL These Datalogic contrast sensors we sell at AutomationDirect all require a connecting cable. Make sure you select the correct cable with correct number of pins in either a straight or a ninety degree connector. The sensor I am using requires a 5 pin 12mm connector cable, I am using the part number listed on the screen: (7000-12361-2150300) The documentation for the sensors state that the center wire will be Grey color, however our sensor cables with 5 pins have a yellow and green wire for the center pin. If you have questions, use a multi meter and check the pin out or call our free technical support here at AutomationDirect. I follow the wiring diagram for this sensor it can be found in the documentation that comes with the sensor, or you can find it on our website. I connect brown to 24 volts positive, blue to 0 volts or negative and the black wire to the input of my PLC X2. I have this setup wired NPN or Positive voltage to the common of the PLC. When the sensor detects a target, it sends a negative signal to the PLC and triggers the input X2. We can change the output of the sensor by following the instructions. First we must unlock the keypad by pressing and holding the set button for 5 seconds. The Unlock LED will turn on allowing us to make changes. Now we can press the positive and negative buttons simultaneously for ten seconds. At two seconds, the Delay LED turns on, and we continue to hold until 10 seconds, the delay LED turns off, we release the positive and negative buttons and we see the Ready and Lock LED's cycle. Now our sensor can be wired with a negative voltage to common. To change back to the original setting, we do the same press both positive and negative buttons simultaneously for ten seconds until the delay LED turns off, we release and the Ready and Lock LED's cycle. Now that the sensor is wired and setup for NPN, let's setup our target. I have a print sheet with tick marks for an example. In this example we setup the sensor to read the black tick marks as the target and the white sheet as the background. In other how to videos I show how the target and background can be reversed. To set the target, I adjust the sensor over the tick mark and press the set button either on the sensor or if I have the remote wire connected, I trigger it with a push button or some other input. When the sensor captures the target, all LED's will be off. Now I move the target so the background can be set, I press the button again and the green LED will blink and when ready the green LED stays illuminated. As you can see, I can now detect the tick marks on this sheet. Simple enough to setup, right? A delay can be set in the sensor to allow the detecting device in our case the PLC input to see the detection pulse in the event the pulses are too short to detect. The sensor will allow the pulse to be extended to 20ms. Now let's setup our delay setting as covered in the instruction manual. I press the positive and negative buttons simultaneously for two seconds until the delay LED turns on as shown. When we sense the same tick marks, we notice that the signal is much slower. To deactivate the delay, we do the same, press both positive and negative buttons simultaneously for two seconds until the delay LED turns off as shown. I hope this how to video was useful. Please follow us to other how to videos on these Datalogic contrast sensors. Thanks and have a great day.



No data returned!
An error has occurred! Please contact support
Videos Home > Datalogic TL Series Contrast Sensor Setup - How To 1 of 4 from AutomationDirect
Contact, Connect & More
Sign Up
to receive:
FREE e-Newsletter
sign up today!
Connect With Us
Social Media Channels:
linkedin    facebook    x    instagram    youtube
Company Information
About Us
Brand Line Card
System Integrator Program
International Sales
Panel Builder Program
Site Help
Company Reviews
Download Price List
Contact Us
Contact Options
1-800-633-0405
Monday - Friday
9 a.m. - 6 p.m. ET
excluding holidays
Career Opportunities
Voted #1 mid-sized employer in Atlanta
We're a great place to work!
Check out our job openings

Need Training?
Affordable Training by Interconnecting Automation
Free Online PLC Training
FREE Video Tutorials
Information & News
What's New / In The News
FREE e-Newsletter
Automation Notebook
Product Literature
White Papers
News, Product and Training Bulletins
E-Books
Shop with confidence
Checked   Safe & Secure
payment methods


We accept VISA, MasterCard, Discover, American Express, PayPal or company purchase orders.
AutomationDirect

BBB Accredited

Voted #1 mid-sized employer in Atlanta
Check out our job openings

Copyright © 1999-2025 AutomationDirect.  ALL RIGHTS RESERVED.
Site Map     Send Us your Feedback     Unsubscribe     Email Preferences     Legal & Business Policies     YouTube Terms of Service
Clear login credentials



Back to Top


spinner Updating...
Info
„