In the previous videos we found connecting
Point of View to a Do-more is easy. You just export the Do-more tags to a CSV
file, and then tell Point of View where to find that file. Point of view calls this Tag Integration. We also saw that Tag integration has some
limitations. Like if you use one item of a structured heap
item the entire size of the heap item gets deducted from your tag license count. The way around that is to use something called
a Driver Sheet. There is a Main Driver Sheet and Standard
Driver Sheet. The difference is the Do-more Main driver
sheet can be filled in with tag information from any Do-more in the system and any combination
of data types for those Do-mores. The Standard driver sheet can only talk to
one Do-more and any data type on that Do-more. But, you can have up to 999 standard driver
sheets so you can create one for every Do-more you need to communicate with. Since the Main Driver sheet can talk to any
combination of devices and data types, you only ever need one of those. The reason for having two different types
of driver sheets is triggering. The Main Driver sheet is updated at a periodic
rate which defaults to every 600ms. The Standard Driver sheet has more options
for triggering when the tags get updated – you can update on an alarm or an event. Or you can schedule updates to do something
like a burst of communications at 2am every morning, stuff like that. With standard driver sheets you can get very
specific with the triggering because you are only talking to one Do-more. In this video, we’ll focus primarily on
the Main Driver sheet. It will be all you need most of the time. And once you understand how to setup the Main
Driver sheet, you’ll be able to do the Standard driver sheet too. Using a Main Driver sheet is easy. You just tell it which element in the CSV
file that you want to access as a standalone element and you’re done. Let’s do a couple examples. You’ll see pretty quick how this comes together
and how easy it is. To create a main driver sheet, just go to
the communications tab, right click on drivers, Add drivers. Select the Domore driver and hit ok. Double click on that driver sheet to edit
it. You can put a tag here to disable the driver
sheet – maybe you only want to access this particular controller type during certain
hours of the day, for example. These are status tags. We’re going to be reading some tags so I
want to keep an eye on any errors we might get during a read so I’ll add a tag here. This Min Max check box will change these columns
to Min and Max which Point of View will use to do scaling in the tags properties dialog. We’ll cover that later in a video on scaling
tags. Down here we enter the tags we want point
of view to retrieve from the Do-more. To do that, we’ll need some Do-more tags,
so let’s create some in Do-more designer. PLC, Memory configuration. Lets add a block of bits. Add Memory block. We’ll call it New BIT Block, it contains
bits, and let’s leave it at 256 bits for this demo. Great. And let’s create another one with strings. We’ll call it New String Block, it’s a
block of strings, let’s make the strings 64 characters each and lets make 27 of those
strings in the block. Great, we have two new memory blocks for Point
of View to access. Let’s add a couple Heap items. First let’s add a PID structure. We’ll call it New PID Item. It’s a PID structure. Now let’s create a Program Structure, but
instead of doing it here, let’s actually create a program. Right click on programs and let’s call it
New Program. Now if we look in the memory dialog, we see
a new heap item called New Program. Perfect. Let save those changes and write them out
to the Do-more. And let’s export the CSV file so we have
all of these new tags. We’ll call that Do-more Tags and we need
to make sure we use the C-more version of the file and store it IN the project folder
so it is easy to find. So all we did here was create two new index-able
memory blocks and two new structured heap items and export the tags to a file. Let’s go back to Point of View and setup
the driver sheet to access those guys. In this column we enter the name we want Point
of View to use. We’ll access the PID Set Point, so let’s
call this PID Set Point. Yes we want to create a new tag and it needs
to be a real. You can see the tag count increment by one. The station is NORMALLY the IP address of
the Do-more. BUT for any user defined memory blocks, like
the ones we just created, you also have to specify the CSV file too. Tell Point of View to look in the current
folder, for the CSV file we just exported from Do-more Designer, colon, IP address. You can also add a colon port number and colon
password if you want to. We’ll take the default port number and don’t
need a password so this is fine. In this column we tell Point of view exactly
what we need to access. If we look in the csv file, we see there are
templates for every memory type. Timers, counter, strings, PID loops, etc. We are going to want the set point of a PID
loop so that looks like its going to be a dot SP. If we scroll down to the bottom we see the
User Heap Items and our PID structure. I’ll copy that name so I don’t mistype
it, Paste it in my driver sheet and append the SP item that we want. And we’ll leave this at read write so we
can do both from Point of view. Well, now that we have defined this tag, let’s
use it. I’ll grab a text box, drop it on the screen. Double click and browse to the new tag we
just created which is going to be in the Project folder. And it was a real and there it is. Double click to select it. Let’s add a title to this box called PID
Setpoint. And while we are here, let’s add the Driver
Sheet Read status to a text box. Great. Save all and run it. Uh oh .. what happened? Why aren’t we getting the result here? Well, if we look this error code up in the
help file, which is under help, communications drivers, DOMORE driver, scroll to the bottom;
we see error 34 is an invalid address error. Back in the driver sheet that means something
is wrong here or here. I got the dot backslash, and the .csv. I tried pinging the IP address and that was
good. The name of the block was copied directly
from the driver sheet and I know set point is SP. This all looks fine. So what’s going on? Well, it turns out that if you have the CSV
file open when you start the app, Point of View can access it. So I’m going to close the csv file – don’t
save any changes - and restart the app. And sure enough, everything is working. If I change the setpoint in Domore, we see
the result in Point of View. And if we change it in Point of View we see
the result appear down on the Do-more. Perfect. So remember that bit about the CSV file being
open that catches me all the time. By the way, You CAN open the CSV file AFTER
you start the app, it just has to be closed while the app is starting so the app can read
all the current Do-more memory configuration info. Here I’ve add the other memory types we
created. We’re extracting bit three from the block
of 256 bits we created, String number 7 and the program done bit from the program module
we created. Note that the indexes are appended; there
aren’t any parenthesis or brackets. On our screen I’ve already created the text
boxes. Each of these just uses the project tag we
just created. Save everything, run the app. If I change string 7 on the Do-more we see
that appear in Point of view. If I change Bit 3 we see that in point of
view. And of course, the program done bit is zero
because we never actually used that program module on the do-more. The key thing to notice here is our tag count. It’s just the 5 tags we created. Just for fun, let’s bring some of these
in via tag integration and see what happens. Project tab, communication, add. We want the Do-more driver, and well call
it Do-more Integrated Tags. Enter the IP Address, and browse to the csv
file we put in in the project folder. A wesome. Now we can see the integrated tags Home tab,
object finder. There’s the folder we just created and here
are all the integrated tags that are available. Let’s create a text box for the PID set
point again, but this time use the integrated tag, not the main driver sheet. Same as before, except now we look under devices,
the new folder we created, heap items and there it is. Click on that, then click on this to select
which member we want to use. We want the Setpoint. You can see the full description of the tag
here. Before we click on OK notice the tag count
is 5. Hit OK and look what happened. The tag count went up by 19! Remember, with tag integration if you use
only one element of a structured heap item, you get penalized for ALL the tags in the
structure. OK, save everything. Run it. If we change the set point on the Do-more
we now see it in both the driver sheet tag and the integrated tag. The only difference is the drive sheet version
of the set point tag only took one tag from the license count. The integrated set point tag cost us 19 tags,
because that was the size of the PID structure. Here’s a question, how many tags would we
loose if we used tag integration to look at the program bit? Let’s try it. Copy the driver sheet version of the done
bit text box and paste it over here. Double click on that to change the tag to
the integrated version. Before we hit OK note that the current tag
count is 24. Hit OK and look what happens. Using that single done bit in the Program
Structure via Tag Integration cost us 147 tags from our license because the program
structure has 147 elements in it! So if you need to access a structured memory
element on the Do-more from Point of view, definitely consider using the Main Driver
sheet. It can save you a lot of tags on your license. What about indexed memory blocks, do they
have the same issue? Let’s find out. Earlier on the Main Driver sheet we created
a Bit3 Tag to pull bit 3 out of an array of 256 bits and we created a string7 tag to pull
string 7 out of a block of twenty seven 64 character strings. Each one of those only used one tag from our
license. And here are the text boxes we used earlier
to display those driver sheet tags. Now what if we do that via tag integration? Will we take a license hit for ALL 256 bits
or ALL 27 string tags in the blocks we created? Let’s find out. Here’s a text box for the Tag integration
version of Bit 3. We browse to the Devices folder – not the
project folder - in the Do-more Integrated Tags folder we created, in Memory blocks and
there’s the New Bit Block we created. We’ll grab bit number 3. The tag count is currently 171, and when we
hit OK and the tag count increases by just ONE- not the entire size of the array or block
of bits, which in this example is 256. Cool. Here’s a text box for the Tag Integration
version of String 7. We browse to the Devices folder, in the Do-more
Integrated Tags folder we created, in Memory blocks and there’s the New String Block
We created. We’ll grab string number 7.The Tag count
is 172, double click an dit also only increased by 1 tag! So accessing blocks of indexed memory or ‘arrays’
on the Do-more via tag integration doesn’t cost us any additional tags. That’s good to know. So the bottom line is you can access all of
the Do-more’s memory via tag integration, but if you want to access a structured memory
element your tag count will go up by the size of the entire structure. So, if you need to minimize tag count when
using structured elements, or want to scale tags automatically as they come into Point
of View, then you’ll need to use a Driver sheet to specify exactly what you want to
bring in. Well, by now you should have a pretty good
idea of how to use a Main Driver Sheet to access memory on the Do-more. To create a standard driver sheet, just go
to the communications tab, right click on the Do more folder, and insert a standard
driver sheet. The only difference is you have more triggering
options and this driver sheet can only talk to ONE Do-more so the IP address of that Do-more
– and CSV file if needed - goes up here. This field is not used on the Do-more driver
and the rest is just like the Main Driver sheet. What you want to call the tag in Point of
View goes here and the exact memory element you want to access goes here. There isn’t a column to control reading
and writing because you control that with these tags up here. If you leave these fields empty, then that
means the tag is readable and writeable at all times. If you need any help, please contact AutomationDirect’s
free award winning tech support during regular business hours. They will be happy to help. And don’t forget the forums – there are